Medicina Intensiva  (English Edition) Medicina Intensiva  (English Edition)
Med Intensiva 2017;41:389 - Vol. 41 Num.6 DOI: 10.1016/j.medin.2016.07.006
Images in Intensive Medicine
Cerebral circulatory arrest detected by insonation of extracranial arteries
Paro circulatorio cerebral detectado mediante la insonación de arterias extracraneales
P. Blanco
Intensive Care Physician, Intensive Care Unit, Hospital “Dr. Emilio Ferreyra”, Necochea, Argentina
Received 22 June 2016, Accepted 02 July 2016

Transcranial doppler (TCD) is able to detect cerebral circulatory arrest (CCA), aiding in confirming the clinical diagnosis of brain death (BD). However, approximately 15% of patients lack optimal bone windows for TCD evaluation. At this instance, intensivists should consider that evaluation of the extracranial arteries in the neck can display the same CCA patterns as interrogation of intracranial arteries. A 54-year-old female patient with history of obesity and arterial hypertension was admitted in coma to the ICU shortly after suffering a massive brainstem hemorrhage. No signs of BD were demonstrated at admission. TCD was not able to recognize intracranial arterial flow due to a lack of optimal bone windows. Doppler interrogation of bilateral internal carotid (ICA) and vertebral artery (VA) in the neck using a linear probe were used to demonstrate the progression of waveforms from a high pulsatility, not corresponding to CCA (Fig. 1A and B), to a reverberating pattern, demonstrated by retrograde diastolic flow (arrows) (Fig. 1C and D), over an observing period of 16h, corresponding to CCA and fully coexisting with the clinical criteria for diagnosing BD.

Figure 1.
(0.05MB).
Acknowledgments

The author would like to thank Mrs. Julieta Vigna for the language guidance.

Copyright © 2016. Elsevier España, S.L.U. y SEMICYUC
Med Intensiva 2017;41:389 - Vol. 41 Num.6 DOI: 10.1016/j.medin.2016.07.006
Cookies Policy
x
To improve our services and products, we use cookies (own or third parties authorized) to show advertising related to client preferences through the analyses of navigation customer behavior. Continuing navigation will be considered as acceptance of this use. You can change the settings or obtain more information by clicking here.